Version 1.0, August 31, 2001, Copyright, Hugh Jack 1993-2001

9.2.1 Multiplexing

 

· Large numbers of inputs and outputs tend to use PLCs inefficiently.

 

· Consider the example of 16 buttons in a keypad. If we connect each button to an input, 16 inputs will be required. But, it is also possible to connect the buttons to 4 outputs and 4 inputs.

 

 

· A similar multiplexing technique can be used for output, as is commonly done for LED digit displays. (Most red LED displays look constant, but they actually flicker at more than 30Hz).